Resultados 1 - 3 de 3
Filtrar
1.
Odovtos (En línea) ; 20(1): 79-88, Jan.-Apr. 2018. tab
Artigo em Inglês | LILACS, BBO | ID: biblio-1091439

RESUMO

Abstract A test frequently used to complement endodontic diagnoses is the cold test; however, in the last 20 years, authors have reported incorrect results within pulp sensitivity tests. Specifically, a high frequency of false results in posterior teeth, were found. The aim of this study was to identify the most appropriate site for the cold test in molar teeth with a need for endodontic treatment, calculating predictive values, accuracy and reproducibility. A cross-sectional study was performed, evaluating 390 subjects. A total of 152 subjects of both genders from the ages of 15-65 years old participated. The ideal standard was established by direct pulp inspection, and the cold test agent used was 1,1,1,2-tetrafluoroethane. The patients were divided into four groups in relation to the molar tooth: (1) mandibular first molar, (2) mandibular second molar, (3) maxillary first molar, and (4) maxillary second molar. 169 teeth and 676 sites were studied. (a) The most appropriate sites for cold test were the middle third of the buccal surface and cervical third of the buccal surface in the mandibular molars with the following results: Middle third of the first molar: Accuracy 0.93, positive predictive value 0.90 and negative predictive value 0.96. Middle third of the second molar: Accuracy 0.93, positive predictive value 1.00 and negative predictive value 0.90. In relation to third cervical the results were: First molar: Accuracy 0.93, positive predictive value 0.89 and negative predictive value 0.97 y second molar: Accuracy 0.93, positive predictive value 1.00 and negative predictive value 0.90. (b) The highest reproducibility was observed in the middle third of the buccal surface with cervical third of the buccal surface in the mandibular second molar (1.00). The most appropriate site and reproducibility of the sites are auxiliary to complement endodontic diagnose with the cold test.


Resumen Una prueba frecuentemente utilizada para complementar los diagnósticos endodónticos es la prueba de frío. Sin embargo, en los últimos 20 años, los autores han reportado resultados incorrectos con las pruebas de sensibilidad pulpar. Específicamente, se ha observado una alta frecuencia de resultados falsos en dientes posteriores. El objetivo del estudio fue identificar el sitio más adecuado para la prueba de frío en dientes molares con necesidad de tratamiento endodóntico, calculando valores predictivos, exactitud y reproducibilidad. Se realizó un estudio transversal donde se evaluaron a 390 sujetos. 152 sujetos de ambos sexos de 15 a 65 años cumplieron con los criterios de inclusión. El estándar ideal que se utilizó en el estudio fue la inspección directa de pulpa en la cámara pulpar y la prueba de frío utilizada fue el 1,1,1,2-tetrafluoroetano. Los pacientes fueron divididos en cuatro grupos en relación al diente molar: (1) primer molar mandibular, (2) segundo molar mandibular, (3) primer molar maxilar, y (4) segundo molar maxilar. En el estudio se evaluaron 169 dientes con 676 sitios. (a) Los sitios más adecuados para la prueba de frío fueron el tercio medio y el tercio cervical de la superficie bucal en los molares mandibulares con los siguientes resultados: Tercio medio del primer molar: Exactitud 0.93, valor predictivo positivo 0.90 y valor predictivo negativo 0.96. Tercio medio del segundo molar: Exactitud 0.93, valor predictivo positivo 1.00 y valor predictivo negativo 0.90. En relación al tercio cervical los resultados fueron: Primer molar: Exactitud 0.93, valor predictivo positivo 0.89 y valor predictivo negativo 0,97 y segundo molar: Exactitud 0.93, valor predictivo positivo 1.00 y valor predictivo negativo 0.90. (b) La más alta reproducibilidad (1.00) se observó entre el tercio medio con el tercio cervical de la superficie bucal en el segundo molar inferior. El sitio más apropiado y la reproducibilidad de los sitios son auxiliares para complementar el diagnóstico endodóntico con la prueba de frío.


Assuntos
Humanos , Masculino , Feminino , Sensibilidade e Especificidade , Temperatura Baixa , Sensibilidade da Dentina/diagnóstico , Dente Molar , Valor Preditivo dos Testes , México
2.
J. oral res. (Impresa) ; 4(4): 249-254, ago.2015. ilus, tab
Artigo em Inglês | LILACS | ID: lil-779226

RESUMO

This study was to evaluate in vivo the accuracy of three electronic apex locators (EALs) in determining working length (WL) using hand files and a wear technique. Thirty two premolars that were completely formed apically and that were scheduled for extraction for orthodontic reasons from patients between ages of 15 and 20 years old were included. Electronic measurement of WL was performed using the EAL according to the manufacturer’s instructions. The following three EAL were used: A. Root ZX II; B. Raypex 5, and C. Propex II. There were significant difference (p=0.0002) when comparing median differences among the three EAL. Statistical analysis revealed significant differences between Root ZX II vs. Raypex 5 and Root ZX II vs. Propex II (p=0.0044; p=0.0002), while between aypex 5 and Propex II, there were no statistically significant differences with respect to the accuracy of the EAL in determining WL (p=0.1087). The present findings suggest that Root ZX II presented the highest agreement rate for determining the final WL...


Estudio fue evaluar in vivo la exactitud de tres localizadores apicales electrónicos(LAEs) para determinar la longitud de trabajo (LT) usando instrumentos manuales y una técnica de desgaste. Treinta y dos premolares con formación apical completa e indicados para extracción por razones ortodóncicas de pacientes de edad entre 15 y 20 años fueron incluidos en el estudio. Seusaron tres LAE; A. Root ZX II; B. Raypex 5, y C. Propex II. Se encontraron diferencias significativas (p=0.0002) cuando se compararon las medianas entre los tres LAE. El análisismostró diferencias entre Root ZX II vs. Raypex 5 y Root ZX II vs. Propex II (p=0.0044; p=0,0002), mientras queentre Raypex 5 y Propex II, no se encontraron diferencias estadísticamente significativas en la determinación de la LT (p=0.1087). Los presentes hallazgos sugieren que Root ZX II mostró la mayor exactitud para determinar la LT final...


Assuntos
Humanos , Masculino , Adolescente , Adulto , Feminino , Adulto Jovem , Ápice Dentário/anatomia & histologia , Cavidade Pulpar/anatomia & histologia , Odontometria/instrumentação , Preparo de Canal Radicular/instrumentação , Equipamentos e Provisões Elétricas
3.
Rev. ADM ; 60(1): 14-18, ene.-feb. 2003. ilus, graf
Artigo em Espanhol | LILACS | ID: lil-350565

RESUMO

El hidróxido de calcio (CaOH2) es un compuesto químico utilizado ampliamente en el tratamiento endodóntico como medicamento intraconducto, pero no existe un criterio que permita a los profesionales de esta área identificar y utilizar el vehículo idóneo para combinarlo, de ello depende la optimización de sus propiedades, entre otras: capacidad para inducir la formación de tejido duro, incidencia para causar oclusión intratubular, acción antibacteriana y capacidad de disolución tisular. Estas propiedades se fundamentan en la capacidad de disociación iónica que tiene el hidróxido de calcio en iones calcio e hidróxilo. La finalidad de este estudio fue analizar por espectrofotometría de absorción atómica y potenciometría el comportamiento del hidróxido de calcio con diferentes vehículos, debido a la relación que existe entre la disociación lenta y sostenida de este compuesto con su efecto como agente terapéutico en tratamientos de apicoformación, eliminación de microorganismos de conductos radiculares infectados con lesión periapical. Se encontró que de los cuatro vehículos estudiados: propilenglicol, polietilenglicol 400, glicerol y suero fisiológico a diferentes tiempos (24 h, 7, 15 y 30 días) el que mostró mejor comportamiento al combinarse con el CaOH2 fue el propilenglicol, presentando una liberación mayor de iones calcio de 580 ppm a los 7 días, seguido por el polietilenglicol con una liberación de 280 ppm, en tanto que el suero fisiológico presentó 270 ppm, finalmente el glicerol sólo liberó 16.6 ppm. Con respecto al valor de pH, se mantuvo en un rango de 12.07 a 12.78 durante los cuatro períodos del análisis


Assuntos
Hidróxido de Cálcio/química , Técnicas In Vitro , Irrigantes do Canal Radicular , Ápice Dentário/crescimento & desenvolvimento , Ápice Dentário , Ápice Dentário/fisiologia , Cavidade Pulpar , Difusão , Espectrofotometria Atômica/métodos , Glicerol , Concentração de Íons de Hidrogênio , Veículos Farmacêuticos , Polietilenoglicóis , Potenciometria , Propilenoglicol , Solução Salina Hipertônica , Cloreto de Sódio , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA